Skip to main content

Outputs for Plasma Model - Mean Residence Time (MRT)

Summary Table for Mean Residence Time (MRT)

Parameters CDISC
Term
IV
Bolus
IV
Infusion
EV Validate
λz
Validate
τ
Observed
Clast
Predicted
Clast
MRTlast MRTIVLST ✓ ✓ ✗ - - ✓ ✗
MRTlast MRTEVLST ✗ ✗ ✓ - - ✓ ✗
MRT∞ MRTIVIFO ✓ ✓ ✗ ✓ - ✓ ✗
MRT∞ MRTEVIFO ✗ ✗ ✓ ✓ - ✓ ✗
MRT'∞ MRTIVIFP ✓ ✓ ✗ ✓ - ✗ ✓
MRT'∞ MRTEVIFP ✗ ✗ ✓ ✓ - ✗ ✓
Note: Rows highlighted in blue represent the default output, while the remaining rows are optional.

MRTlast

MRTlast is defined as the mean residence time based on observed data only, which is generally used when λz fitting fails or is unreliable. It is a robust, non-extrapolated metric.

For IV Bolus,


For IV Infusion, MRTlast is adjusted by subtracting half the infusion duration (Ti),


For Extravascular, MRTlast follows the same derivation as IV Bolus, however, it represents not only the process of distribution and elimination but also absorption,


MRT∞

MRT∞ is defined as the mean residence time extrapolated to infinite per observed Clast, which requires a valdiate λz.

For IV Bolus,


For IV Infusion,


For Extravascular,


MRT'∞

MRT'∞ is defined as the mean residence time extrapolated to infinite per predicted Clast, which is used for sensitivity analysis when Clast is considered as outlier.

During the derivation, replace Clast with Cpred (including AUCpred and AUMCpred accordingly).